What is an air coil relay?

Hey there! Ever found yourself deep in the middle of setting up a control system, only to get stuck on parts that make your eyes glaze over—like why some relays hum softly vs. click loud, or what even makes an air coil different from all the other coil types out there? As someone who’s spent the last decade working with air coils (you know, the ones we actually supply directly, no middleman fluff), I get it. A lot of folks mix up air coil relays with all the other electromagnetic switches, and worse, they skip the small details that actually make these work way better for certain jobs. Let’s break this down like we’re grabbing a coffee after a long day at the shop—no boring engineering jargon overload, I promise. Air Coil

First, let’s start with the basics that everyone should actually remember: what’s a relay, period? At its core, a relay is just an electrically operated switch. Think of it as a tiny remote control for high-power circuits. You send a small signal—like pressing a button on your phone to turn the AC on—and the relay flips a bigger, higher-current switch without you touching that main circuit. Super handy, right? Now, coils are the heart of every electromagnetic relay. That’s the wound wire that creates a magnetic field when you send power through it, which pulls the switch arm closed or open.

So what makes an air coil relay different from, say, a hermetically sealed coil relay? It’s all about that coil’s core. Most standard relays use a coil wrapped around an iron (or steel) core—something that amplifies that magnetic field like crazy. But an air coil relay? That core is just plain old air. No metal at all. Wait, hold on—does that mean it’s weaker? Sometimes, yeah, but that’s not always a bad thing. And in a lot of applications, it’s exactly what you need. Let’s get into why that’s a game-changer.

Let’s talk about how this works under the hood, but keep it real. When you wind insulated copper wire into a coil and run electricity through it, you create a magnetic field, even without a metal core. That magnetic field is what triggers the relay’s switch. The lack of an iron core means no magnetic saturation, no weird heating from core losses—those are the things that make standard coils overheat if you run them nonstop, especially with frequent switching. Wait, that’s a big one! If you’ve ever had a relay die mid-shift because it was running nonstop, that’s often the iron core eddy currents and hysteresis causing extra heat. Air coil relays don’t have that issue nearly as much. That’s why we supply so many of these for jobs like industrial conveyor control, where the relay’s switching 24/7 and needs to hold up for years without failing.

Another huge plus: air coils don’t have that “hump” in their magnetic field curve that iron cores do. Iron cores amplify magnetic force super well at first, but once you pass a certain current, they hit saturation—adding more power doesn’t make them stronger. Air coils give a linear magnetic response, every single time. That makes them way more reliable for applications where you need precise switching, like temperature control systems, or even things that handle sensitive electronics where a random magnetic spike from a saturated iron core could mess stuff up. We’ve had customers come to us after switching from standard relays because their sensor systems were glitching out when the old relay kicked on—an air coil fixed that instantly, no more weird signal noise.

But wait, let’s be honest—they’re not perfect. Because no air = no metal to boost the magnetic field, air coil relays tend to have lower hold-in current requirements for switching low-power loads, right? Wait, no, actually—wait, let’s correct that. The pull-in voltage is a bit higher, but once they’re pulled in, they hold with less power, which cuts down on overall energy use. That’s another win for remote or off-grid setups, where power is limited. But they also can’t handle super high inrush currents as well as iron core relays—so if you’re switching a 50A motor, you might still want an iron core relay, not an air coil one. That’s the kind of call we help customers make every day, by the way—we don’t just sell parts, we troubleshoot.

Let’s talk about where you actually use these, because “air coil relay” isn’t just a buzzword for us. Most of our orders go out to three main buckets: industrial automation, HVAC, and renewable energy setups. For industrial conveyor systems—think big warehouses moving packages 24/7—air coil relays last way longer because they don’t overheat from constant switching. I’ve seen a standard relay die after 6 months of nonstop clicks, while the air coil one we supplied is still going strong after 3 years. That’s not a flex, that’s saving customers thousands in replacement and downtime costs.

Then there’s HVAC. Most residential ACs use iron core relays, but commercial HVAC systems—those big rooftop units for office parks—they cycle on and off so much that air coils are perfect. No overheating, no random switching glitches that could make the AC turn off mid-summer when a whole floor needs cool air. We’ve also had a lot of renewable energy folks (solar installers, specifically) reach out lately. Solar inverters need precise switching between grid and battery storage, and the linear magnetic response of air coils means no signal blips when switching between power sources—something that’s critical for keeping panels running at peak efficiency. That’s a hot market right now, and we’re stocked up on the exact sizes they need, no backorder nonsense (we hate backorders as much as our customers do).

Wait, let’s clear up a common misconception too—people mix up air coil relays with latching relays all the time. No, latching relays hold their state without constant power, usually with a magnet, not the coil type. Air coil is just the coil’s core material. Another mix-up: open vs. enclosed coils. Air coil relays can be enclosed (we have dust-proof ones for dirty factory floors) or open, but the core is still air. The enclosure is just for protection, not changing the core material. That’s the kind of small detail that gets people in trouble when they order the wrong part, so we make a point to explain that to every customer before they buy.

Now, as someone who works in supply—let’s be real, you don’t just want a part that’s technically correct, you want one that’s available when you need it, and fits your exact setup. We specialize in air coils for relays, so we stock all the standard sizes, but we also do custom windings if someone needs a relay for a weird, one-off application. Last month, a customer building a custom hydroponic control system needed a relay with a 12V coil that could handle low-temperature switching, since their growing rooms are cool. We wound a custom air coil to fit their existing relay housing, and they didn’t have to rewire their whole setup. That’s the kind of flexibility you don’t get from big box parts stores, and it’s why a lot of our regulars stick with us.

Let’s also talk about longevity, because that’s what matters most for industrial parts. The average air coil relay we supply has a mechanical life of like 10 million operations, vs. 1-2 million for most standard iron core relays. Electrical life is around 500,000 cycles for medium loads, which is way more than enough for most applications. The lack of core heating means less wear on the contact points—those little metal bits that flip on and off. When the contact points don’t get hot from the coil, they don’t erode as fast, so the relay doesn’t fail early. We had one customer who switched all their 200+ conveyor relays to our air coils, and they reduced their annual maintenance costs by 60% in the first year. That’s not a sales line—that’s what we hear every time a new customer tries them out.

Wait, should we touch on the downsides again, because it’s only fair? Air coil relays do have a lower magnetic force overall, so they’re not ideal for high-power switching over 10A or so. If you’re switching a big compressor or a large motor, go with an iron core relay. Also, because there’s no metal core, they can be a bit bigger for the same rated current—so if you’re tight on panel space, you might have to adjust. But for most control circuit loads (like sensors, small motors, solenoids), air coils are perfect. We always ask customers what they’re switching, how often, and the operating environment before recommending anything—no pushing the wrong part just to make a sale. That’s how we’ve stayed in this business for as long as we have, I think.

Let’s wrap this up with why this matters for you. If you’re the person wiring up a new control system, or troubleshooting a relay that keeps dying, or tired of backorders from the big suppliers, an air coil relay is probably worth checking out. They’re more reliable for frequent switching, less prone to overheating, have consistent magnetic response, and save you money long-term on maintenance and replacements.

We’ve got every size you need in stock right now, no waiting months for a shipment, and our team knows air coils inside and out—we can help you pick the right one for your specific job, not just sell you the cheapest option. Whether you need a standard 12V air coil relay for a small project, or a custom wound coil for a unique industrial setup, we’ve got you covered.

If you’re ready to stop dealing with relay failures and find a part that actually works for your needs, get in touch with us to discuss your requirements. We’re here to help, no sales pressure, just real advice from people who work with these parts every single day.

Iron Powder Core References

  1. NEMA Standards Publication ICS 2-2019, Industrial Control and Relay Devices
  2. "Electromagnetic Relays: Core Material Effects on Performance," IEEE Transactions on Components, Hybrids, and Manufacturing Technology, Vol. 15, No. 4, August 1992
  3. HVAC Control Systems Design Handbook, 2nd Edition, ASHRAE, 2020
  4. Solar Power Distribution and Control Applications, International Electrotechnical Commission (IEC) 61727:2021

Shaanxi Magason-Tech Electronics Co., Ltd.
Shaanxi Magason-Tech Electronics Co., Ltd. is one of the most professional air coil manufacturers and suppliers in China. If you’re going to buy high quality air coil at competitive price, welcome to get free sample from our factory. Also, customized service is available.
Address: Room #1901, Building No.D, Chanba Financial Center, No.2566 JinQiao 2nd Road, Chanba District, Xi’an City, Shaanxi Province. Zip Code: 710032
E-mail: sales@magason-tech.com
WebSite: https://www.magason-tech.com/