Posted in

What is the priming process for a screw pump?

If you’ve ever worked with fluid handling systems, chances are you’ve encountered a screw pump—whether you realize it or not. These workhorses move everything from lubricating oil in industrial machinery to wastewater in municipal treatment plants, and they’re prized for their steady, pulse-free flow. But here’s the thing that trips up a lot of new operators (even some seasoned ones): priming. Mess that up, and your screw pump could overheat, wear out prematurely, or even fail entirely before you’ve moved a single gallon of fluid. As a screw pump supplier, I’ve seen this mistake so many times that I make it a point to walk every new client through exactly how the priming process works, step by step. Let’s break it down, no stuffy engineering jargon, just straight talk that actually makes sense. Screw Pump

First, let’s get clear on what priming even is. A screw pump, unlike a centrifugal pump, doesn’t rely on centrifugal force to move fluid. It uses two or three intermeshing screws (wait—yeah, some are twin-screw, some triple) that rotate to create sealed chambers, trapping fluid, moving it along the screws, and pushing it out the discharge side. But to do that, those chambers can’t have air in them. If there’s air, the screws will just spin against nothing, no fluid gets trapped, and you end up with that annoying thudding, noisy noise that tells you your pump isn’t working right. That’s “air binding,” and priming is how you fill every single chamber with the fluid you’re moving, displacing all the air before you flip the switch on the motor.

Now, before we dive into the actual steps, let’s talk about when you need to prime. This isn’t a set-it-and-forget-it task. You have to prime every time the pump is stopped long enough for the suction line to drain. If your suction line is full of fluid when you start the pump, you might not need to prime every time, but most real-world setups—especially ones that handle thin or viscous fluids—will require priming regularly. I’ve had clients with screw pumps for waste oil tell me they skip priming once and end up replacing two screws within six months. It’s that avoidable.

Let’s walk through the actual priming process, the way we teach it to every client who buys a pump from us. First step: prep the pump and the surrounding lines. This sounds basic, but I’ve seen people skip it. Make sure the pump casing (the big outer shell that holds the screws) is vented. You’ll find a priming vent plug on top of the casing—this is where air will escape when you add fluid. Also, check the suction line for any leaks; a tiny leak here can pull air in while you’re priming, making the whole process useless. If you’re priming a pump that’s been sitting for a while, give the screws a quick spin by hand (after turning the power off, obviously) to make sure they move freely. If they’re stuck, don’t force it—call a tech, not your supplier, to avoid bending the screws.

Second step: fill the pump casing and suction line with the process fluid. This is where that vent plug comes in. Loosen the priming vent plug first, then pour or pump fluid into the casing through the priming port (another plug on the side or top, usually). Keep adding fluid until it starts spilling out of the vent plug—this means all the air inside the casing is gone, and fluid has filled every chamber around the screws. Now, here’s a pro tip from someone who sells these pumps: don’t use a fluid that’s not the one you’re pumping. I once had a client use water to prime a pump that handles heavy crude oil. When they started the pump, the water mixed with the crude, got stuck in the narrow gaps between the screws, and caused the pump to seize up for three days. Ouch. Stick to your actual process fluid—even if it means a little more work, it saves you a way bigger headache later.

Third step: seal everything up and check for leaks. Once fluid is flowing out of the vent plug, tighten that vent plug back down, then make sure the suction line connections are tight. You don’t want air getting back in while the pump runs. Now, here’s a step that’s easy to miss: open the suction valve and the discharge valve. Wait—discharge valve? If you leave that closed, pressure will build up inside the pump, which can blow seals or damage the motor. I’ve seen this happen too. Some people think keeping the discharge valve closed keeps fluid in, but no—for screw pumps, you need a little pressure relief. Open both valves before you start the motor.

Fourth step: start the pump and monitor the initial flow. Flip the motor on gently—don’t yank it to full speed right away. You should see steady, smooth fluid flow out of the discharge line within a few seconds. If it sputters or has gaps, that means you missed some air. Stop the pump, go back, check the vent plug, and re-prime. Run the pump at low speed for the first minute or two just to make sure the flow stays consistent. Once it’s steady, you can ramp up to your normal operating speed.

Wait, but what about different types of screw pumps? Because not all screw pumps are the same. Twin-screw pumps (the most common for general industrial use) have a male and female screw, right? Their priming process is almost exactly what I just walked through. Triple-screw pumps, which are often used for lubrication in large engines or hydraulic systems, are a little different. They have a central main screw and two smaller outer screws, so their casing is a bit longer. The key there is to make sure you fill all the gaps between the central screw and the outer ones—triple-screw pumps hold more air, so you might need to add a little more fluid, or use a priming pump that feeds directly into the suction line to speed things up. I’ve seen operators try to prime a triple-screw pump by just pouring fluid on top, and it only gets half the chambers. That’s why I always ask clients what fluid they’re moving and what type of pump they have before I give specific steps.

Now, what are the biggest mistakes people make when priming screw pumps? Let’s list the ones I see every week. First, not venting the casing. If you skip the vent plug, air gets trapped, and you’ll never get the pump primed right. Second, using the wrong fluid for priming. Like that crude oil client I mentioned—mixing fluids causes all sorts of issues. Third, running the pump without priming, which is the big one. Screw pumps are designed to run with fluid as a lubricant between the screws; dry running means metal-on-metal contact, and even a few seconds can cause significant wear. I had a client once run a pump dry for 10 seconds and end up with $5,000 in replacement parts. It’s not worth it. Fourth, over-tightening the vent plug. That sounds silly, but if you strip the threads on the priming port, you’ll have a leak forever. Hand-tight is all you need—don’t use a wrench unless it’s still leaking, and even then, just a quarter turn.

Also, what about self-priming screw pumps? Wait, some screw pumps are self-priming, right? You don’t have to hand-fill them. But that doesn’t mean you can skip checking! Self-priming pumps have a built-in chamber that traps air and creates a vacuum to pull fluid from the suction line. But if that chamber is damaged, or the suction line has a leak, the self-priming feature won’t work. I get calls all the time from people with self-priming screw pumps saying “it won’t prime” and it turns out their suction line has a tiny pinhole leak. So even self-priming pumps need a quick check before you start—don’t just hit the button and walk away.

Let’s also talk about maintenance-related priming issues. Over time, the seal on the priming vent plug can wear out, or the suction line can build up residue (if you’re pumping sludge or viscous fluids) that blocks flow. If you’re priming regularly and noticing it’s taking longer each time, that’s a sign you need to clean the suction line or replace the vent plug seal. I remind all my clients to add priming checks to their weekly maintenance schedule—10 minutes of checking now saves hours of downtime later.

As a screw pump supplier, my job isn’t just to sell a pump—it’s to make sure it works for you. That means walking you through every step, even the ones that seem “obvious” to someone who works with these every day. I’ve had clients come to me frustrated because their pump failed, and when we dig in, it’s almost always a priming mistake—they skipped a step, used the wrong fluid, or didn’t check for leaks. It’s such a preventable issue.

If you’re in the market for a screw pump, or you’re having trouble with priming your current one, reach out. We can walk you through your specific setup, whether you’re handling water, oil, wastewater, or any other fluid, and make sure you’ve got the right pump and the right priming process for your needs. Don’t let a avoidable priming mistake turn your fluid handling system into a headache—let’s get it right the first time.

Centrifugal Pump References:

  1. Karassik, I. J., McGuire, J., & Messina, J. P. (2007). Pump Handbook (4th ed.). McGraw-Hill Education.
  2. Hydraulic Institute. (2019). Centrifugal and Positive Displacement Pump Installation, Operation, and Maintenance Standards.
  3. Ramadhyani, S. (2012). Fluid Mechanics and Thermal Systems for Engineers. CRC Press.
  4. Wilson, E. M., & Karassik, I. J. (1989). Pump Selection: A Guide to Application. Butterworth-Heinemann.
  5. American National Standards Institute. (2020). ANSI/HI 9.6.1 Rotodynamic Pumps for NPSH Requirements.

Zhejiang Yonjou Technology Co., Ltd.
Zhejiang Yonjou Technology Co., Ltd. is known as one of the most professional screw pump manufacturers and suppliers in China, with more than 30 years’ experience. Please feel free to buy high quality screw pump for sale here from our factory. For price consultation, contact us.
Address: No.780, Oubei Road, Yongjia County, Wenzhou City, Zhejiang Province, China
E-mail: sales@yonjou.com
WebSite: https://www.yonjoupump.com/