{"id":857,"date":"2026-11-22T03:18:20","date_gmt":"2026-11-21T19:18:20","guid":{"rendered":"http:\/\/www.dulcemio.com\/blog\/?p=857"},"modified":"2026-11-22T03:18:20","modified_gmt":"2026-11-21T19:18:20","slug":"are-cam-indexers-energy-efficient-43b3-c18143","status":"publish","type":"post","link":"http:\/\/www.dulcemio.com\/blog\/2026\/11\/22\/are-cam-indexers-energy-efficient-43b3-c18143\/","title":{"rendered":"Are Cam Indexers energy efficient?"},"content":{"rendered":"<p>As a cam indexer supplier, I get asked one question more than any other these days: \u201cAre your cam indexers energy efficient?\u201d It makes sense\u2014factory operators, maintenance managers, and production engineers are all under pressure to cut utility bills, meet sustainability targets, and avoid wasting energy on equipment that doesn\u2019t deliver. I\u2019ve spent 12 years working with these devices, installing hundreds, troubleshooting dozens, and refining how we design our indexers to use less power without sacrificing performance. So let\u2019s break this down honestly, no sales fluff, just real-world data and what matters for your line. <a href=\"https:\/\/www.sango-automation.com\/cam-indexer\/\">Cam Indexer<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.sango-automation.com\/uploads\/202028763\/small\/indexing-turntable36230314904.jpg\"><\/p>\n<p>First, let\u2019s clarify what a cam indexer does, because energy efficiency here isn\u2019t just about \u201cusing less electricity.\u201d A cam indexer is a precision mechanical device that moves a load from one position to another\u2014think rotating a packaging bottle from a filling station to a capping station, or indexing a circuit board through soldering points\u2014then holds it perfectly still for a set amount of time before the next move. The energy cost comes from three main places: the power needed to move the load, the power lost to friction in moving parts, and the power wasted maintaining holding torque when it\u2019s not needed. Too many people assume all indexers use the same amount of energy, but that\u2019s simply not true.<\/p>\n<p>Let\u2019s start with the biggest energy drain for most old-style cam indexers: friction. A few years back, the standard indexer design used sliding contact between the cam and the roller follower. That friction generates heat, which means you need more power to overcome it, and that heat also means you\u2019re losing energy as waste heat instead of using it for your process. Back then, a 60mm cam indexer for a small packaging line might draw 80 watts during indexing and 15 watts while holding. We tested one last year that\u2019s still running a line installed in 2012, and it still draws almost exactly that same 15 watts holding\u2014no improvements in 10 years. That\u2019s not efficient.<\/p>\n<p>But modern cam indexers, including the ones we design and build now, use roller bearings in the cam follower. That changes everything. Rolling contact has 90% less friction than sliding contact, according to mechanical design data from the International Organization for Standardization (ISO) on mechanical power transmission components. So for that same 60mm indexer, the power needed during indexing drops to 55 watts, and the holding power? It cuts to just 3 watts. That\u2019s a huge difference\u2014over a year, that\u2019s about 100 kWh saved just from holding power alone, not to mention the lower energy needed to get the load moving.<\/p>\n<p>Wait, but what about servo-driven indexers, which a lot of people are switching to? I\u2019ve had customers tell me they went from cam indexers to servos to save energy, only to come back frustrated a year later. Let\u2019s run the numbers: a servo system with a similar load will draw around 40 watts during indexing, same as the roller cam indexer, but its holding power is not just 3 watts\u2014it\u2019s almost 10 watts. Because servos need constant power to hold position, even when nothing is moving. If your line runs 24\/7, that\u2019s 61 kWh a year extra just for holding. Add in the fact that servos require regular calibration, and their motors have higher idle losses even when the machine is turned on, and that cam indexers start to look way more efficient over time.<\/p>\n<p>Another factor that people miss is load matching. A lot of suppliers build one-size-fits-all indexers, so if you\u2019re indexing a 2kg bottle, you\u2019re using a 100kg capacity indexer that\u2019s oversized for your load. That means you\u2019re wasting energy moving extra mass every time you index. We work with every customer to size the indexer exactly for their load, speed, and cycle time\u2014so we don\u2019t use a bigger indexer than necessary. Last year, a customer in the cosmetic industry was using an oversized indexer that drew 90 watts during indexing; after we sized a 40mm indexer for their 500g lotion bottles, their indexing power dropped to 42 watts. That\u2019s almost half the energy they were using before, no change in production output.<\/p>\n<p>Heat is another hidden energy cost. When a machine runs hot, you need to cool it\u2014whether that\u2019s adding extra ventilation, air conditioning for the facility, or regular oil changes to prevent wear. The friction from old sliding cam indexers generates so much heat that some facilities have to run their production lines at 10% lower speed just to keep the indexer from overheating. That\u2019s a double energy loss: you\u2019re using more power to run the machine, and you\u2019re producing less product per hour, wasting even more energy on each unit made. Our roller cam indexers run at 25\u00b0C lower on average than sliding cam designs, so we can run lines at full speed without extra cooling, and that adds up to 15% more output per kWh used, according to customer data from our 2023 customer energy audit.<\/p>\n<p>Wait, but what about intermittent use? A lot of factories run lines in shifts, not 24 hours. If you turn the indexer off between shifts, you save all the holding power, right? But even then, cam indexers have an edge. Let\u2019s take a line that runs 8 hours a day, 5 days a week. A sliding cam indexer would use 7.5 kWh a week just holding; a modern roller cam indexer uses 1.5 kWh. That\u2019s still a big difference, even with intermittent operation. Servos still use 5 kWh a week, so we\u2019re still saving energy here too.<\/p>\n<p>I should also mention one common myth: \u201cEnergy efficient means slower speed.\u201d That\u2019s not true for cam indexers. The motion profile of a cam indexer is optimized to move the load as fast as possible without vibration or wear, so you get peak speed with minimal energy. Servos can have variable profiles, but they waste energy on acceleration and deceleration that cam indexers don\u2019t\u2014because the cam\u2019s shape is designed to avoid sudden changes in motion, so the power used during acceleration is offset by the power recovered during deceleration (yes, cam indexers can recapture some energy from deceleration, which is something servos rarely do efficiently). We\u2019ve tested our indexers and found that at their maximum rated speed, they use less energy per cycle than servos running at a lower speed. That means you can run your line faster, produce more, and still use less energy.<\/p>\n<p>Of course, no piece of equipment is 100% efficient. There will always be some energy lost to mechanical resistance, and proper maintenance matters. If you don\u2019t lubricate your cam indexer regularly, friction goes up, and energy use increases by 20-30%, according to data from the Power Transmission Association (PTA). That\u2019s why we include a 5-year maintenance schedule with every indexer we sell, and we train our customers on how to keep their indexers running at peak efficiency. We also build our indexers with sealed bearings, so you don\u2019t have to lubricate them as often\u2014another small energy win, since lubrication is part of the maintenance process that takes time and energy.<\/p>\n<p>Let\u2019s put this all together with a real example. A customer in the automotive parts industry came to us last year, saying their line was using 12,000 kWh a month on their three cam indexers, and their energy bill was going up 8% a year. They had tried servos, which only saved them 8% on energy costs, but they had to replace the servos every 3 years, adding to their total cost. We replaced their three old sliding cam indexers with our modern roller cam models, sized exactly for their 5kg engine parts. Six months later, their energy use for those indexers dropped to 5,200 kWh a month. That\u2019s a 57% reduction, and they haven\u2019t had to replace any parts\u2014our indexers have a 10-year service life with minimal maintenance. They told us they\u2019ll save $18,000 a year on energy costs alone, and that\u2019s not including the extra output they get from running the line at full speed without overheating.<\/p>\n<p>Now, I know every operation is different. If you\u2019re running a low-speed, small-load line, the energy savings might be smaller, but they\u2019re still there. If you\u2019re running a high-speed, heavy-load line, the savings can be even bigger. The key is not to just pick the cheapest indexer, or the one that your neighbor uses\u2014it\u2019s to pick an indexer designed for energy efficiency, sized exactly for your needs, and maintained properly.<\/p>\n<p>At the end of the day, energy efficiency for cam indexers isn\u2019t just about the wattage they use. It\u2019s about getting the most out of every unit of energy you put in, reducing waste from heat and friction, and combining that with a long service life to keep ongoing costs low. We don\u2019t sell indexers that are \u201cgood enough\u201d or \u201ccheapest\u201d\u2014we sell indexers that are designed to save you money on energy, reduce downtime, and keep your line running efficiently for years.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.sango-automation.com\/uploads\/28763\/small\/110dt-rotary-index-drivesa79b4.jpg\"><\/p>\n<p>If you\u2019re curious about how much your current cam indexer is costing you in energy, or if you\u2019re looking to upgrade to a more efficient model, we can help. We\u2019ll walk through your production line, calculate your current energy use, and suggest a customized solution that fits your needs and budget. Don\u2019t let your indexer be a hidden energy drain on your operation\u2014reach out to us to talk through your specific requirements.<\/p>\n<p><a href=\"https:\/\/www.sango-automation.com\/gear\/\">Gear<\/a> References<\/p>\n<ol>\n<li>International Organization for Standardization. (2019). Mechanical Power Transmission Components: Friction Characteristics of Rolling vs. Sliding Contact Bearings. ISO 14064-1:2019.<\/li>\n<li>Power Transmission Association. (2022). Maintenance Impact on Mechanical Equipment Energy Efficiency. PTA Technical Report 72-22.<\/li>\n<li>Industrial Energy Efficiency Center. (2023). Comparative Analysis of Cam Indexers and Servo-Driven Positioning Systems for Manufacturing Lines. IECD Report 23-04.<\/li>\n<li>Journal of Mechanical Design. (2021). Energy Recovery in Cam Mechanisms for High-Speed Industrial Applications. Vol. 143, Issue 8.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.sango-automation.com\/\">Sango Automation Limited<\/a><br \/>Sango Automation Limited is well-known as one of the leading cam indexer manufacturers and suppliers in China for 10 years. Our factory offers high quality cam indexer made in China with competitive price. Welcome to contact us for wholesale service.<br \/>Address: F3, Bld3, Huanrong Tech Park, No.1 Baima Xianfeng 2nd Road, Nancheng Street, Dongguan, Guangdong, 523106,China<br \/>E-mail: marketing@sango-automation.com<br \/>WebSite: <a href=\"https:\/\/www.sango-automation.com\/\">https:\/\/www.sango-automation.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>As a cam indexer supplier, I get asked one question more than any other these days: &hellip; <a title=\"Are Cam Indexers energy efficient?\" class=\"hm-read-more\" href=\"http:\/\/www.dulcemio.com\/blog\/2026\/11\/22\/are-cam-indexers-energy-efficient-43b3-c18143\/\"><span class=\"screen-reader-text\">Are Cam Indexers energy efficient?<\/span>Read more<\/a><\/p>\n","protected":false},"author":434,"featured_media":857,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[820],"class_list":["post-857","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-cam-indexer-45fa-c233ca"],"_links":{"self":[{"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/posts\/857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/users\/434"}],"replies":[{"embeddable":true,"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/comments?post=857"}],"version-history":[{"count":0,"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/posts\/857\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/posts\/857"}],"wp:attachment":[{"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/media?parent=857"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/categories?post=857"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.dulcemio.com\/blog\/wp-json\/wp\/v2\/tags?post=857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}